Introduction

The Communicator DD (1CH/2CH) (21001/20937) Dongle allows you to integrate any power supply that provides an auxiliary 12V DC output and supports Digital Dimming control into your existing Smart network. Up to two channels per device are supported (CH1, CH2) by the Communicator DD. A 3-pin Amphenol X-Lok Mini Series connector is used to connect to the power supply. 


Table of Contents

  • Core Functions
  • Configuration
  • Statistics

Core Functions

The digital dimming dongle is a 3-pole dongle as described in the introduction, designed to attach to any device supporting external control to enable Smart network features for the connected device.


These Smart network features include target output values, configurable startup behavior, device identification via flicker, power transfer percentage between channels (2CH only), repetition of reported output values, access to statistics, and the ability to define devices in networks and groups to remotely control specific (groups of) devices with output values.

The 1CH version only supports devices with a single output. The 2CH version can control two outputs. The 1CH version cannot be used with devices that support more than one output.


Configuration

After powering-up the device, the Communicator DD (2CH) Dongle should be visible in the Bever App. Simply add the device to a Smart network (1-30) and group (1-30) and it is ready to control your power supply.


BASIC Tab
Default output

Channel 1 base output
100%
Default output for channel #1
Channel 2 base output
0%
Default output for channel #2 (2CH only)
Channel 3 base output
0%
- Reserved for future purposes -


ADVANCED Tab
Output behaviour
Keep last received percentageOFFPrevents the output from reverting to the fallback percentage when the validity of the level packet for the corresponding channel expires 
Device identification
Allow device flickerONAllow output of set "Channel to flicker" to flicker on request via app (go to flicker minimum value, then to flicker maximum value and return to value before flicker, adjustable in EXPERT Tab)
Channel to flicker1Channel used for flicker to identify when device is selected in Bever App (1CH only allows channel 1)


EXPERT Tab
Power transfer
Ch2 to 1 Power transfer percentage0%Transfer part of  possible output power of channel 2 to channel 1 on top of output channel 1 (2CH only). Drivers can split the total output power over the number of channels evenly. However, when in this case channel 2 is off, the set percentage of maximum output power of channel 2 is provided on top of set output power of channel 1
Ch3 to 1 Power transfer percentage
0%- Reserved for future purposes -
Repeat same percentage
Repeat same percentageOFFRepeat to report target output percentage to driver for every supported channel for the set repeat interval
Repeat interval5 secondsInterval between report repeating output percentage to driver of same percentage for every supported channel.
Statistics update
Statistics update interval 10 secondsInterval between update statistics from driver
Flickering behaviour
Flicker minimum value10%Minimum value to dim towards when flicker to identify is triggered of defined channel
Flicker maximum value70%Maximum value to dim towards when flicker to identify is triggered of defined channel
Delay (ms)500msDelay between reporting target ouput percentages from Flicker minimum value to Flicker maximum value to original value


Statistics

The following tables provide a description of the objects in the statistics page.

BASICS Tab

Name

Description

Unit

Dongle sent to driver CH 1

Last reported percentage

Last valid target output communicated to the driver for channel 1

%

Time since last reported

Time since last target output has been send to the driver for channel 1

hh:mm:ss

Dongle sent to driver CH 2

Last reported percentage

Last valid target output communicated to the driver for channel 2 (2CH only)

%

Time since last reported

Time since last target output has been send to the driver for channel 2 (2CH only)

hh:mm:ss

Dongle sent to driver CH 3

Last reported percentage

- Reserved for future purposes -

%

Time since last reported

- Reserved for future purposes -

hh:mm:ss

Driver feedback

Time since dimming update

Time since last percentage is reported to driver

hh:mm:ss

Driver on time (only extracted if supported)

Total lamp on time

Measured time lamp emitting light

Hours

Time since update

Time since value of Total lamp on time is read from driver

hh:mm:ss

Driver active energy (only extracted if supported)

Driver active energy

Energy consumption of driver since first startup

Wh

Time since update

Time since value of Driver active energy is read from driver

hh:mm:ss

Driver temperature (only extracted if supported)

Internal temperature

Measured internal temperature of driver

°C

Time since update

Time since value of Internal temperature is read from driver

hh:mm:ss

External temperature

Measured external temperature of external thermometer connected to driver

 

Time since update

Time since value of External temperature is read from driver

hh:mm:ss

Uptime dongle

Uptime

Total time of device powered

hh:mm

Time since last start-up

Total time device is powered since last start-up

hh:mm

Startups

Startups

Total number of start-ups of device

-



ADVANCED Tab

Name

Description

Unit

Data received via Smart Network

Time since four level received

Time since last four level packet is received

hh:mm:ss

For channel 1

Last received percentage

Last received percentage extracted from four level packet for output channel 1

%

Last used valid percentage

Last reported valid output percentage to driver for output channel 1

%

For channel 2 (2CH only)

Last received percentage

Last received percentage extracted from four level packet for output channel 2

%

Last used valid percentage

Last reported valid output percentage to driver for output channel 2

%

For channel 3

Last received percentage

- Reserved for future purposes -

%

Last used valid percentage

- Reserved for future purposes -

%

Driver output current (only extracted if supported) 

Output current

Current measured by Driver at output

mA

Time since update

Time since last output current readout

hh:mm:ss

Driver output voltage (only extracted if supported) 

Total lamp on time

Measured time lamp emitting light

Hours

Time since update

Time since value of Total lamp on time is read from driver

hh:mm:ss

Driver dimming brightness (only extracted if supported) 

Dimming brightness

Brightness emitted set by Driver (0-200). Divided by 2 to get the percentage last received from the dongle

-

Time since update

Time since last brightness readout

hh:mm:ss

Driver output power (only extracted if supported) 

Output power

Power measured by Driver at output

W

Time since update

Time since last output power readout

hh:mm:ss

Driver startup level (only extracted if supported) 

Dimming level startup

Value of startup brightness (0-200) of driver before dongle starts controlling brightness

-

Time since update

Time since value of External temperature is read from driver

hh:mm:ss


EXPERT Tab

Name

Description

Unit

Inform info

Remaining validity last reported

Remaining time of validity of last received valid four level for channel 1

Seconds

Remaining validity last reported

Remaining time of validity of last received valid four level for channel 2 (2CH only)

Seconds

Remaining validity last reported

- Reserved for future purposes -

Seconds

Driver info (only extracted if supported)

Input frequency

Input frequency measured at startup by driver at input

Hz

Time since update

Time since last input frequency readout

hh:mm:ss

Power factor

The efficiency factor from AC input to DC output

-

Time since update

Time since last input power factor readout

hh:mm:ss

Input current

Current measured by Driver at input

mA

Time since update

Time since last input current readout

hh:mm:ss

Input voltage

Voltage measured by driver at input

VAC

Time since update

Time since last input voltage readout

hh:mm:ss

Input power

Power measured by driver at input

W

Time since update

Time since last input power readout

hh:mm:ss

Failure mode

Failure code of detected failure by driver

-

Time since update

Time since last failure mode readout

hh:mm:ss

Driver target channel (only extracted if supported)

Target channel

Channel set on to exchange data with

-

Time since update

Time since target channel readout

hh:mm:ss

Dimming level target channel

Brightness value (0-200) read from driver of target channel

-

Time since update

Time since dimming level target channel readout

hh:mm:ss

Digital dimming buffer (only extracted if supported)

Fifo size

Number off digital dimming packets in buffer left to handle by driver

-

Fifo add failures

Number of failed attempts do add digital dimming packet in buffer

-

Model info (only extracted if supported)

Model info byte

Model type number of driver

-

Time since update

Time since model info byte readout

hh:mm:ss

IOSet info (only extracted if supported)

IOset ch1 offset perc

Read set percentage of maximum output current of channel 1

%

Time since update

Time since value of IOset ch1 offset perc is read from driver

hh:mm:ss

IOset ch2 offset perc

Read set percentage of maximum output current of channel 2 (2CH only)

%

Time since update

Time since value of IOset ch2 offset perc is read from driver (2CH only)

hh:mm:ss

IOset ch3 offset perc

- Reserved for future purposes -

%

Time since update

- Reserved for future purposes -

hh:mm:ss

Power transfer (only extracted if supported)

Transfer offset 2 to 1

Read set percentage of transfer power from channel 2 to channel 1 (2CH only)

%

Time since update

Time since last transfer offset 2 to 1 readout

hh:mm:ss

Transfer offset 3 to 1

- Reserved for future purposes -

%

Time since update

- Reserved for future purposes -

hh:mm:ss